故障/Bug #1350
NW Steering fault should show "CAT III Dual" in inop system on STS page
Start date:
05/29/2025
% Done:
0%
Reporter:
John Ramos
Phone:
09063489642
PlannedFixDate:
06/04/2025
SoftVersion:
a320-1.9.15
FlightPhase:
N/A
100%Reproducible:
YES
ReproductionSteps:
Init:
Step:
Issue:
Expect:
IssueType:
SoftSystem(FunctionLogic)
Description
NW Steering fault should show "CAT III Dual" in inop system on STS page
Files
Updated by Zhou Yanan 2 months ago
- Status changed from 待观察/Remains to 新建/New
- Assignee changed from Zhou Yanan to 金 亮
Updated by 金 亮 2 months ago
- File NW_STRG_FAULT.png NW_STRG_FAULT.png added
The FMGC module has been associated with the avail signal of the brakes NW,
but after active 32_NW_STEER_FAULT malfunction, the valid and avial signal of NW no change, need brakes' engineer to continue investigating and handling.