故障/Bug #1479
Abrupt/Shaking movement then motion goes down
0%
Init:
Step:
Issue:
Expect:
Description
upon checking we noticed that the motion cabinet turned off and no signs of power.
We checked the breaker and there was a sign of burn.
We were still able to power on the motion because at first we thought it just needed power cycle, and the crew still managed to engage motion, however we still continue inspecting and then we found out that there was a burnt wire on the breaker.
We immediately inform CSS team and they advised us to not to use the motion temporarily and fixed the wire first.
They also gave us instruction, which is to check the junction box of all 6 actuators. And everything was OK. We also sent pictures to them.
CSS team next instruction is to fix the burnt wire,
then power ON the motion cabinet,
and lastly contact them immediately on whats app so that they can remote connect to check the logs and analyze the problem.
After the fix
Please ask confirmation to CSS if the sim is already Ok to use.
Files
Updated by sim tech 5 days ago
During disassembly of the faulty breaker, We found out that the burn was caused by improper installation of the wires on the breaker. The terminal logs that holds the wires were not tight enough.
These are 3 wires in pairs that supplies the motion system in 3 phase. One of them was not tight enough resulting to imbalance supply of 3 phase.
After replacement, tested the motion and the sim was working fine with no abnormalities.
Updated by Zhou Yanan 4 days ago
- File test.jpg test.jpg added
- Status changed from 待观察/Remains to 反馈/FeedBack
- Assignee changed from Zhou Yanan to sim tech
Received. You did an excellent job! We recommend that you could purchase a tool similar to the one shown in my picture - the Power Quality Recorder - and install it at the front stage of the transformer. This will facilitate the monitoring of the overall voltage.